Iterative reconstructed ultra high pitch CT pulmonary angiography with cardiac bowtie-shaped filter in the acute setting: Effect on dose and image quality

  • 1. Vancouver General Hospital, Department of Radiology, Jim Pattison Pavilion South, 899 West 12th Ave. Room G861, Vancouver BC V5Z 1M9 (Canada)
  • 2. 19899 Grand View Drive, Topanga, CA 90290 (United States)

Description

Purpose: To evaluate the effect of a cardiac bowtie-shaped filter in an ultra high pitch CTPA protocol at 100 kV on image quality and radiation dose. Materials and methods: Retrospective study of 100 patients referred for CTPA. 50 patients scanned with a standard 100 kV protocol at pitch 2.8 (Protocol A) and 50 patients scanned with a 100 kV protocol at pitch 3.2 with a cardiac bowtie-shaped filter (Protocol B). All other scanning parameters kept constant. Images from both groups reconstructed with filtered back projection and iterative reconstruction. Central pulmonary vessel attenuation and background noise were quantitatively measured and signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated. Two radiologists performed qualitative assessment grading visualization of the pulmonary vasculature and noise level. CTDIvol and DLP were recorded and effective dose was calculated. Results: CTDIvol, DLP and effective dose were significantly (p < 0.0001) lower in Protocol B (2.3 ± 0.5 mGy, 78.4 ± 16.5 mGy cm, 1.4 ± 0.3 mSy, respectively) compared to Protocol A (4.3 ± 0.5 mGy, 152.0 ± 19.6 mGy cm, 2.7 ± 0.3 mSy, respectively). Protocol B had significantly (p < 0.0001) higher noise than Protocol A (23.8 ± 6.9 HU vs 36.8 ± 7.3 HU) and lower SNR (11.8 ± 3.7 HU vs 19.2 ± 8.1 HU) and CNR (10.3 ± 3.7 HU vs 24.9 ± 13.4 HU) but there was no significant difference in the subjective visualization of the pulmonary vasculature (p = 0.63). Furthermore, iterative reconstruction significantly (p < 0.0001) improves image noise (29.4 ± 5.5 HU from 36.8 ± 7.3 HU). Conclusion: The addition of a cardiac bowtie-shaped filter with an ultra high pitch CTPA protocol at 100 kV resulted in a 48% dose reduction without significantly affecting diagnostic image quality. In addition, the use of iterative reconstruction significantly improves image quality by reducing noise permitting the possibility for further dose reduction strategies

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2013.04.043

Additional details

Identifiers

DOI
10.1016/j.ejrad.2013.04.043;
PII
S0720-048X(13)00267-2;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
82
Journal Issue
9
Journal Page Range
p. 1571-1576
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.