Published August 2008 | Version v1
Miscellaneous

Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

  • 1. Malaysian Nuclear Agency, Bangi (Malaysia). Radiochemistry and Environment Group

Description

This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

Availability note (English)

Available at Malaysian Nuclear Agency (Nuclear Malaysia) Document Delivery Service; Ainon@nuclearmalaysia.gov.my; Nuclear Malaysia formerly known as Malaysian Institute for Nuclear Technology Research (MINT]

Additional details

Publishing Information

Publisher
Malaysian Nuclear Agency
Imprint Place
Bangi (Malaysia)
Imprint Pagination
5 p.

Conference

Title
Nuclear Malaysia R and D 2008 Seminar
Dates
26-29 Aug 2008
Place
Bangi (Malaysia)