Published 1975
| Version v1
Report
Restricted
Power and phase monitoring system for the lower hybrid phased array heating system on ATC machine
Description
A four waveguide phased array slow wave structure has been constructed to couple microwave energy into plasma in the ATC Tokamac at Princeton. Theory has indicated that the coupling of power into the plasma column is a strong function of the imposed fourier spectrum at the antenna aperture. To optimize heating, and to verify theoretical results, a precision amplitude and phase monitoring system has been designed and constructed. The system data output is routed to an IBM 1800 computer where the fourier spectrum in n/sub parallel/ space is computed for discrete increments of time during an RF pulse. Computer output data is used to update the adjustment of transmission line parameters in between pulses
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS.
Files
Additional details
Publishing Information
- Imprint Pagination
- 20 p.
- Report number
- CONF-751125--116
Conference
- Title
- IEEE 6. symposium on engineering problems of fusion research.
- Dates
- 17 Nov 1975.
- Place
- San Diego, California, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 7253785
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ATC DEVICES; CONTROL SYSTEMS; HYBRID RESONANCE; PLASMA HEATING; WAVEGUIDES
- Descriptors DEC
- CLOSED PLASMA DEVICES; HEATING; RESONANCE; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Notes
- Available from NTIS. $3.50.