ISX-B neutral beam injector experiment on a prototype beam line
Creators
- 1. Oak Ridge National Laboratory, Fusion Energy Division, Oak Ridge, Tennessee 37830
Description
Two PLT-injector-type duoPIGatron sources, modified further by shaping the beam-forming apertures, have been tested and experimented on a protype beam line similar to the ISX-B neutral beam injection system. The accelerator column modification has resulted in an increase of the beam power transmission efficiency from that of the straight-bore aperture by 50%. Maximum neutral beam powers achieved on a 28-cm-diam target simulating the ISX-B plasma, located 4.1 m downstream from the source, are approx. =910 kW of H0 at an accelerator power of 42 kV and 61 A and approx. =1020 kW of D0 at 43 kV and 55 A. Measurements have been made to investigate the following: the effects on beam optics of aperture shape, aspect ratio, and different ions (H+ or D+); the distribution of beam power deposition along the beam line; ion species compositions; and background pressure behavior due to scrape-off beam particles. The injectors have been shown to be characterized by an optimum perveance of 6 x 10-6 AV/sup -3/2/ for an effective extraction area of 142 cm2 (1799 apertures), which is approximately invariant over the beam energies tried
Additional details
Publishing Information
- Journal Title
- J. Appl. Phys.
- Journal Volume
- 51
- Journal Issue
- 4
- Series
- J. Appl. Phys.
- Journal Page Range
- 1984-1993
- ISSN
- 0021-8979
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 11553594
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ACCELERATORS; APERTURES; BEAM INJECTION; BEAM OPTICS; DATA; EFFICIENCY; ENERGY LOSSES; IONS; PENNING ION SOURCES; PLT DEVICES; QUANTITY RATIO
- Descriptors DEC
- CHARGED PARTICLES; CLOSED PLASMA DEVICES; INFORMATION; ION SOURCES; OPENINGS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES