Published 2000 | Version v1
Report Open

Capillary optics as an x-ray condensing lens. An alignment procedure

  • 1. Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Frascati, RM (Italy)
  • 2. CNR, Montelibretti, RM (Italy). Ist. di Strutturistica Chimica
  • 3. P.N. Lebedev Physical Institute RAS, Moscow (USSR)

Description

The procedure of capillary lens alignment is described in detail. The theoretical basis of capillary optics is given in the framework of a comparative analysis of monocapillary and polycapillary optics. The results of x-ray distribution scanning behind the capillary lens for various angle planes, together with the fitting results, are presented. A qualitative explanation is given for the discrepancy between the expected and observed divergences of x-ray beams transmitted by the capillary lens

Availability note (English)

Available from INIS in electronic form

Files

31065713.pdf

Files (133.8 kB)

Name Size Download all
md5:1c8e1583cd2bc1af21462fa914e53d86
133.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
11 p.
Report number
LNF-P--00-03

INIS

Country of Publication
Italy
Country of Input or Organization
Italy
INIS RN
31065713
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
ALIGNMENT; BEAM OPTICS; OPTICAL PROPERTIES; OPTICAL SYSTEMS; X-RAY SOURCES
Descriptors DEC
PHYSICAL PROPERTIES; RADIATION SOURCES