Assessment of aortic diameter in Marfan patients. Intraindividual comparison of 3D-Dixon and 2D-SSFP magnetic resonance imaging
Creators
- 1. Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg (Germany)
- 2. Philips GmbH Market DACH, Hamburg (Germany)
- 3. Department of Vascular Medicine, University Heart and Vascular Center Hamburg, Hamburg (Germany)
- 4. Institute of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)
Description
To compare the accuracy and precision of 3D-Dixon and 2D-SSFP MR-imaging for assessment of aortic diameter in Marfan patients. This prospective single-center study investigated respiratory-gated 3D-Dixon and breath-hold 2D-SSFP non-contrast MR-imaging at 3 T in 47 Marfan patients (36.0 ± 13.2 years, 28♀,19♂). Two radiologists performed individual diameter measurements at five levels of the thoracic aorta and evaluated image quality on a four-grade scale (1 = poor, 4 = excellent) and artifacts (1 = severe, 4 = none). Aortic root diameters acquired by echocardiography served as a reference standard. Intraclass correlation coefficient, Bland-Altman analyses, F-test, t-test, and regression analyses were used to assess agreement between observers and methods. Greatest aortic diameters were observed at the level of the sinuses of Valsalva (SOV) for 3D-Dixon (38.2 ± 6.8 mm) and 2D-SSFP (38.3 ± 7.1 mm) (p = 0.53). Intra- and interobserver correlation of diameter measurements was excellent at all aortic levels for both 3D-Dixon (r = 0.94-0.99 and r = 0.94-0.98) and 2D-SSFP (r = 0.96-1.00 and r = 0.95-0.99). 3D-Dixon-derived and 2D-SSFP-derived diameter measurements at the level of the SOV revealed a strong correlation with echocardiographic measurements (r = 0.92, p < 0.001 and r = 0.93, p < 0.001, respectively). The estimated mean image quality at the level of SOV was higher for 2D-SSFP compared to that for 3D-Dixon (3.3 (95%-CI: 3.1-3.5) vs. 2.9 (95%-CI: 2.7-3.1)) (p < 0.001). Imaging artifacts were less at all aortic levels for 3D-Dixon compared to 2D-SSFP (3.4-3.8 vs. 2.8-3.1) (all p < 0.002). Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP MR-imaging provide accurate and precise aortic diameter measurements. We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations of the aortic root. Respiratory-gated 3D-Dixon and breath-hold 2D-SSFP imaging provide accurate and precise aortic diameter measurements in patients suffering from Marfan syndrome. Imaging artifacts are stronger in 2D-SFFP imaging than in 3D-Dixon imaging. We recommend 3D-Dixon imaging for monitoring of aortic diameter in Marfan patients due to fewer imaging artifacts and the possibility of orthogonal multiplanar reformations.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-022-09162-yAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 33
- Journal Issue
- 3
- Journal Page Range
- p. 1687-1697
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 54032624
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; AORTA; CHEST; COMPARATIVE EVALUATIONS; CORRELATIONS; HEREDITARY DISEASES; IMAGE PROCESSING; IMAGE SCANNERS; MAGNETIC FIELDS; MEASURING METHODS; NMR IMAGING; REGRESSION ANALYSIS; RESPIRATION; SINUSES; SIZE; ULTRASONOGRAPHY
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; CAVITIES; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; MATHEMATICS; ORGANS; PROCESSING; STATISTICS