Published 1987 | Version v1
Book

A unique manual method for emergency offsite dose calculations

  • 1. Pennsylvania Power and Light Co., Two North Ninth Street, Allentown, PA (USA)

Description

This paper describes a manual method developed for performance of emergency offsite dose calculations for PP and L's Susquehanna Steam Electric Station. The method is based on a three-part carbonless form. The front page guides the user through selection of the appropriate accident case and inclusion of meteorological and effluent data data. By circling the applicable accident descriptors, the user circles the dose factors on pages 2 and 3 which are then simply multiplied to yield the whole body and thyroid dose rates at the plant boundary, two, five, and ten miles. The process used to generate the worksheet is discussed, including the method used to incorporate the observed terrain effects on airflow patterns caused by the Susquehanna River Valley topography

Additional details

Publishing Information

Publisher
Health Physics Society.
Imprint Place
McLean, VA (USA)
Imprint Title
Proceedings of the twentyfirst midyear topical meeting of the Health Physics Society
Imprint Pagination
vp.
Journal Page Range
p. 143-152.

Conference

Title
power reactor health physics.
Acronym
21. mid-year topical meeting of the Health Physics Society
Dates
13-17 Dec 1987.
Place
Bel Harbour, FL (USA).

Optional Information

Secondary number(s)
CONF-871202--.