Published 2009 | Version v1
Book

Fibre optics for metrology in nuclear research reactors applications to dimensional measurements

  • 1. CEA, Nuclear Energy Division, DPC/SCP/LILM Bat 467 CEA Saclay, 91191 Gif / Yvette Cedex (France)
  • 2. CEA, Nuclear Energy Division, Reactors Studies Department, Cadarache, 13108 St. Paul Lez Durance (France)
  • 3. SCK.CEN, ANS/ARI, Boeretang 200, 2400 Mol (Belgium)

Description

In-situ measurement is a key issue for advanced irradiation programs in Material Testing Reactors (MTR). In that prospect, Optical Fibre Sensors (OFS) can feature unique intrinsic properties that bring substantial advantages over conventional sensing approaches. A preliminary condition to the development of OFS is to ensure that the Radiation Induced Absorption (RIA) of the light in the fibre does not exceed a pre-defined threshold. We report the results of a long lasting irradiation experiment, at higher dose than previously reported: up to a fast neutron fluence of 1020 n/cm2 and an ionising dose of 16 GGy, carried out on various fibres, including hollow core photonic band gap (PBG) fibres, single-mode (SM) and multimode (MM) fibres. If we consider that RIA measurements losses < 10 dB are acceptable for the development of OFS in harsh environments such as MTRs, it can be stated that multimode and single mode fibres exist that fulfill this criteria, as far as the most favourable spectral region, in the 800 to 1100/1200 nm wavelength range is considered. Possible applications of OFS sensors in the vicinity of research reactors core are presented. We focus then on the project of dimensional measurement, based mainly on low coherence interferometry with an Extrinsic Fabry Perot. We report some first irradiation experiments on commercial sensors, then we present the adapted schemes designed to avoid the consequences of the radiation induced silica compaction. On that basis, we have set the configuration, built some first prototypes in metallic capillaries and we have worked on the anchoring of the sensor on a sample. We present the prototypes developed and the first results of testing accuracy. The irradiation of some sensors anchored on a stainless steel plate is planed in 2009 in the BR2 reactor facility in Mol/Belgium using a dedicated irradiation rig. The purpose of this experiment will be to assess, in a first step, the survivability and the level of signal drift under high radiation when a stable strain is applied on the sensor. (authors)

Availability note (English)

Available from doi:

Additional details

Identifiers

Publishing Information

Publisher
IEEE - Institute of Electrical and Electronics Engineers
Imprint Place
New York (United States)
ISBN
978-1-4244-5207-1
Imprint Pagination
8 p.

Conference

Title
1. International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications
Acronym
ANIMMA 2009
Dates
7-10 Jun 2009
Place
Marseille (France)

Optional Information

Notes
24 refs.