Published October 2006 | Version v1
Journal article

Development of neutron measurement system for nd/nt fuel ratio measurement in ITER experiments

  • 1. Tohoku University, Sendai 980-8579 (Japan)
  • 2. JAEA, Tokai, Naka, Ibaraki 319-1195 (Japan)
  • 3. Osaka University, Yamadaoka 2-1, Suita 565-0871 (Japan)

Description

The possibility of measurement of fuel ratio from the DT/DD reaction ratio with a neutron spectrometer in the International Thermonuclear Experimental Reactor was studied. The results of neutron transport calculations using the Monte Carlo N-particle [MCNP, a general Monte Carlo N-particle transport code, version 4C, LA-13709, edited by J. F. Briesmeister, Los Alamos National Laboratory, 2000] code system indicated the possibility of DD spectrum separation from the scattered/energy-degraded neutrons derived from DT neutrons by selection of the measurement location and collimator design. A time-of-flight spectrometer was used in this study. An experiment using DD and DT neutrons from an accelerator was conducted at the Japan Atomic Energy Agency Fusion Neutronics Source facility. Using a sophisticated circuit with three discriminators for the first detector, separation of DD and DT neutron components of the spectrum in the megahertz region was confirmed experimentally

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
77
Journal Issue
10
Journal Page Range
p. 10E726
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2006 American Institute of Physics