Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63
Creators
- Reft, Chester1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Alecu, Rodica1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Das, Indra J.1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Gerbi, Bruce J.1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Keall, Paul1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Lief, Eugene1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Mijnheer, Ben J.1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Papanikolaou, Nikos1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Sibata, Claudio1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- Van Dyk, Jake1, 2, 3, 4, 5, 6, 7, 8, 9, 10
- 1. London Regional Cancer Centre, Ontario (Canada)
- 2. East Carolina University School of Medicine, Greenville, North Carolina (United States)
- 3. University of Arkansas Medical Sciences (United States)
- 4. Netherlands Cancer Institute, Amsterdam, (Netherlands)
- 5. New York University Medical Center, New York (United States)
- 6. Virginia Commonwealth University, Richmond, Virginia (United States)
- 7. University of Minnesota Medical School, Minneapolis, Minnesota (United States)
- 8. University of Pennsylvania, Philadelphia, Pennsylvania (United States)
- 9. U.S. Oncology, Texas Cancer Center, Sherman, Texas (United States)
- 10. University of Chicago, Chicago, Illinois 60637 (United States)
Description
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for radiation oncology patients with high-Z hip prostheses
Additional details
Identifiers
- DOI
- 10.1118/1.1565113;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 30
- Journal Issue
- 6
- Journal Page Range
- p. 1162-1182
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35024346
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- BIOLOGICAL MATERIALS; CARCINOMAS; DOSIMETRY; IRRADIATION PROCEDURES; OPTIMIZATION; PELVIS; PROSTHESES; RADIOTHERAPY
- Descriptors DEC
- BODY; DISEASES; MATERIALS; MEDICAL SUPPLIES; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; RADIOLOGY; THERAPY
Optional Information
- Notes
- (c) 2003 American Association of Physicists in Medicine.