There is a newer version of the record available.

Published 2024 | Version v1
Journal article

The impact of image contrast, resolution and reader expertise on black hole identification in Multiple Sclerosis

  • 1. Department of Advanced Biomedical Sciences, University of Naples "Federico II", Via Pansini 5, 80131, Naples (Italy)
  • 2. Department of Neurosciences and Reproductive and Odontostomatological Sciences, University of Naples "Federico II", Naples (Italy)
  • 3. Departament of Radiology and Diagnostic Imaging of Universidade Federal Do Triângulo Mineiro (UFTM), Uberaba (Brazil)
  • 4. Research Department of Universidade de Uberaba (UNIUBE), Uberaba (Brazil)
  • 5. Department of Radiology and Nuclear Medicine, MS Center Amsterdam, Amsterdam Neuroscience, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam (Netherlands)
  • 6. Department of Human Neurosciences, Sapienza University, Rome (Italy)

Description

In the neuroradiological work-up of Multiple Sclerosis (MS), the detection of "black holes" (BH) represent an information of undeniable importance. Nevertheless, different sequences can be used in clinical practice to evaluate BH in MS. Aim of this study was to investigate the possible impact of different sequences, resolutions, and levels of expertise on the intra- and inter-rater reliability identification of BH in MS. Brain MRI scans of 85 MS patients (M/F = 22/63; mean age = 36.0 ± 10.2 years) were evaluated in this prospective single-center study. The acquisition protocol included a 3 mm SE-T1w sequence, a 1 mm 3D-GrE-T1w sequence from which a resliced 3 mm sequence was also obtained. Images were evaluated independently by two readers of different expertise at baseline and after a wash-out period of 30 days. The intraclass correlation coefficient (ICC) was calculated as an index of intra and inter-reader reliability. For both readers, the intra-reader ICC analysis showed that the 3 mm SE-T1w and 3 mm resliced GrE-T1w images achieved an excellent performance (both with an ICC ≥ 0.95), while 1 mm 3D-GrE-T1w scans achieved a moderate one (ICC < 0.90). The inter-reader analysis showed that each of the three sequences achieved a moderate performance (all ICCs < 0.90). The 1 mm 3D-GrE-T1w sequence seems to be prone to a greater intra-reader variability compared to the 3 mm SE-T1w, with this effect being driven by the higher spatial resolution of the first sequence. To ensure reliability levels comparable with the standard SE-T1w in BH count, an assessment on a 3 mm resliced GrE-T1w sequence should be recommended.

Additional details

Identifiers

Publishing Information

Journal Title
Neuroradiology
Journal Volume
66
Journal Issue
8
Journal Page Range
p. 1345-1352
ISSN
0028-3940
CODEN
NRDYAB