Published January 31, 1978
| Version v1
Report
Open
Kilowatt Isotope Power System: component report for the Ground Demonstration System Accumulator
Description
The Model Number ORC1A3A01 System Accumulator for the Kilowatt Isotope Power System was expulsion tested and demonstrated to be in compliance with the requirements of Sundstrand Explusion Test Procedure, TP 400. Test requirements of TP 400 were extracted from the Kilowatt Isotope Power System, Ground Demonstration System Test Plan
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.Files
12585463.pdf
Files
(1.3 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:325cf54b7145dcf9c18273c36ed913b1
|
1.3 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 32 p.
- Report number
- DOE/ET/33001--T2
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12585463
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- BIPHENYL; ELECTRIC BATTERIES; EXPERIMENTAL DATA; FLUID FLOW; NITROGEN; OPERATION; PERFORMANCE TESTING; PRESSURE DEPENDENCE; RADIOISOTOPE BATTERIES; RADIOISOTOPE HEAT SOURCES; RANKINE CYCLE; SATELLITES; SPACECRAFT POWER SUPPLIES
- Descriptors DEC
- AROMATICS; DATA; DIRECT ENERGY CONVERTERS; ELECTRONIC EQUIPMENT; ELEMENTS; ENERGY SOURCES; ENERGY STORAGE SYSTEMS; HYDROCARBONS; INFORMATION; NONMETALS; NUMERICAL DATA; ORGANIC COMPOUNDS; POWER SUPPLIES; TESTING; THERMODYNAMIC CYCLES