Effect of window function for measurement of ultrasonic nonlinear parameter using fast fourier transform of tone-burst signal
- 1. Dept. of Mechanical Engineering, Hanyang University, Seoul (Korea, Republic of)
Description
In ultrasonic nonlinear parameter measurement using the fast Fourier transform(FFT) of tone-burst signals, the side lobe and leakage on spectrum because of finite time and non-periodicity of signals makes it difficult to measure the harmonic magnitudes accurately. The window function made it possible to resolve this problem. In this study, the effect of the Hanning and Turkey window functions on the experimental measurement of nonlinear parameters was analyzed. In addition, the effect of changes in tone burst signal number with changes in the window function on the experimental measurement was analyzed. The result for both window functions were similar and showed that they enabled reliable nonlinear parameter measurement. However, in order to restore original signal amplitude, the amplitude compensation coefficient should be considered for each window function. On a separate note, the larger number of tone bursts was advantageous for stable nonlinear parameter measurement, but this effect was more advantageous in the case of the Hanning window than the Tukey window
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 35
- Journal Issue
- 4
- Series
- 14 refs, 6 figs, 1 tab
- Journal Page Range
- p. 251-257
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 46131165
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- FOURIER TRANSFORMATION; LEAKS; RELIABILITY; SIGNALS; ULTRASONIC TESTING
- Descriptors DEC
- ACOUSTIC TESTING; INTEGRAL TRANSFORMATIONS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING; TRANSFORMATIONS