Detector designing method of compensated neutron logging tool under two kinds of neutron source
Creators
- 1. Energy and dynamic institute of Xi'an jiaotong university, Xi'an (China)
- 2. Technology Center of China Petroleum Logging Co. Ltd., Xi'an (China)
- 3. Chang-Qing Department of China Petroleum Logging Co., Ltd., Xi'an (China)
Description
It influences parameter designing of compensated neutron detector using isotopic neutron source or neutron generator. Designing method of determining neutron detector source distance is discussed in the paper. Measurement results are compared which done in 3700 calibration vessel under the condition of two kinds of neutron source. The mathematic module is given out to get formation porosity by the ration of counting rate where curve-fitting algorithm is used. It is showed that compensated neutron logging can be realized by using neutron generator instead of isotopic neutron source. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 30
- Journal Issue
- 1
- Journal Page Range
- p. 75-79
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 42093628
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- ALGORITHMS; CALIBRATION; COMPARATIVE EVALUATIONS; COUNTING RATES; DISTANCE; MATHEMATICAL MODELS; NEUTRON DETECTORS; NEUTRON GENERATORS; NEUTRON LOGGING; NEUTRON SOURCES; POROSITY
- Descriptors DEC
- EVALUATION; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; NEUTRON SOURCES; PARTICLE SOURCES; RADIATION DETECTORS; RADIATION SOURCES; RADIOACTIVITY LOGGING; WELL LOGGING
Optional Information
- Notes
- 5 figs., 3 tabs., 4 refs.