Quantitative measurement of local cerebral blood flow in humans by positron computed tomography and 15O-water
Creators
- 1. Department of Radiological Sciences, UCLA School of Medicine
Description
A noninvasive method that employs 15O-water and positron-computed tomography (PCT) was used to measure quantitative local cerebral blood flow (lCBF) in man. 15O-Water (about 30-50 mCi) was introduced through a single-breath inhalation of 15O-carbon dioxide or through an intravenous bolus injection of 15O-water. A sequence of five 2-min PCT scans was initiated at the time of tracer administration. A series of 15-20 blood samples (1 ml each) was withdrawn from the radial artery of the subject over a period of 10 min. Oxygen-15 radioactivities in the blood samples were immediately counted in a well counter to give an input function, which together with the projection data collected by PCT were processed to provide images of 1CBF and local water distribution volume. The method was found to be convenient to use and gave good-quality images of 1CBF. Quantitative values of 1CBF in images were 59 +/- 11 and 20 +/- 4 ml/min/100 g for gray and white matter, respectively, with a gray-to-white matter ratio of 2.93 and a global flow value of 42 +/- 8 ml/min/100 g. Distribution volume of water was 0.85 +/- 0.03, 0.76 +/- 0.03, and 0.81 +/- 0.02 ml/g respectively, for gray matter, white matter, and whole brain
Additional details
Publishing Information
- Journal Title
- J. Cereb. Blood Flow Metab.
- Journal Volume
- 3
- Journal Issue
- 2
- Series
- J. Cereb. Blood Flow Metab.
- Journal Page Range
- 141-153
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15009643
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD FLOW; BRAIN; CARBON DIOXIDE; INHALATION; LABELLED COMPOUNDS; OXYGEN 15; POSITRON COMPUTED TOMOGRAPHY; TRACER TECHNIQUES
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BODY; CARBON COMPOUNDS; CARBON OXIDES; CENTRAL NERVOUS SYSTEM; CHALCOGENIDES; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; EVEN-ODD NUCLEI; INTAKE; ISOTOPE APPLICATIONS; ISOTOPES; LIGHT NUCLEI; MINUTES LIVING RADIOISOTOPES; NERVOUS SYSTEM; NUCLEI; ORGANS; OXIDES; OXYGEN COMPOUNDS; OXYGEN ISOTOPES; RADIOISOTOPES; TOMOGRAPHY