Published 2014 | Version v1
Miscellaneous

Suppression of nonlinear-response in differential-CT system for SACLA

  • 1. Japan Synchrotron Radiation Research Institute (JASRI), Sayo, Hyogo (Japan)
  • 2. RIKEN SPring-8 Center, Sayo, Hyogo (Japan)

Description

A differential current-transformer (CT) system was developed to measure an electron charge without substantial noise coming from a klystron power source in the x-ray free electron laser, SACLA. At a place downstream of the third bunch-compressor (BC3) in SACLA, nonlinearity was found in a measured electron-charge value with the differential- CT system. The reason for this uncertainty was confirmed to be the nonlinear response of a preamplifier in the CT system due to a short pulse duration of 400 ps. Therefore, a 15 dB attenuator or a 30m-long coaxial cable as a low pass filter was inserted before the preamplifier input. The linearity of the differential-CT system was improved to be about 10% for the attenuator case, which is an allowable error in the operation monitoring of SACLA. The linearity for the coaxial cable case was 4%, which is sufficient accuracy to estimate the accelerated electron-charge. (author)

Part of:
Proceedings of the 11th annual meeting of Particle Accelerator Society of Japan

Additional details

Publishing Information

Imprint Title
Proceedings of the 11th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
[1393 p.]
Journal Page Range
[4 p.]

Conference

Title
11. annual meeting of Particle Accelerator Society of Japan
Dates
8-12 Aug 2014
Place
Aomori (Japan)

Optional Information

Notes
5 refs., 8 figs.