Comparison of radiation field irradiated by different focusing modes of γ-knife

  • 1. Institute of Radiation Medicine, Shandong Academy of Medicine Sciences, Jinan (China)

Description

Objective: To compare the single-shot fields irradiated by three focusing modes of γ-knife and explore the approaches for improving the quality of stereotactic radiosurgery. Methods: GAFCHROMIC® EBT3 mode flushing-free film was used to measure the single-shot fields irradiated by multi-source static focusing modes, multi-source single-axis rotating focusing mode and single-source double-axis rotating focusing mode of γ-knife. Also the uniformity and penumbra of the single-shot fields were compared. Results: The 2D dose distribution of the single-shot fields irradiated by three focusing modes of γ-knife was different. In the axis (x, y, z), the rang of penumbra axial length ratios of multi-source static focusing modes, multi-source single-axis rotating focusing mode and single-source double-axis rotating focusing mode were 0.13-0.48, 0.17-0.33 and 0.28-0.54, in the diagonal direction of the wings plane (NSD, PSD), were 0.31-0.39, 0.38-0.43 and 0.54-0.72, respectively; the penumbra axial length ratio of single-source double-axis rotating focusing mode was bigger than in multi-source static focusing modes and multi-source single-axis rotating focusing mode. On the no-wings plane, the area ratios of 80% dose curve enveloped and 50% dose curve enveloped (A80%/A50%) were 0.40, 0.47 and 0.19, on the wings plane, were 0.61, 0.53 and 0.35, respectively. The field uniformity of multi-source static focusing modes and multi-source single-axis rotating focusing mode were superior to single-source double-axis rotating focusing mode. Conclusions: Considering dose distribution of the single-shot fields, the multi-source static focusing modes devices and the multi-source single-axis rotating focusing mode devices should be preferred, when important tissues and organs are adjacent to the target areas. Compared with single-source double-axis rotating focusing mode, both multi-source static focusing modes and multi-source single-axis rotating focusing mode could make more target areas to be surrounded by high dose region. (authors)

Additional details

Publishing Information

Journal Title
Chinese Journal of Radiological Medicine and Protection
Journal Volume
35
Journal Issue
5
Journal Page Range
p. 384-388
ISSN
0254-5098

Optional Information

Notes
3 figs., 1 tab., 11 refs.; http://dx.doi.org/10.3760/cma.j.issn.0254-5098.2015.05.018