Published October 1982 | Version v1
Journal article

Solution of an integral equation encountered in rotation therapy

  • 1. Karolinska Sjukhuset, Stockholm (Sweden). Dept. of Hospital Physics
  • 2. Stockholm Univ. (Sweden)

Description

An integral equation relating the lateral absorbed dose profile of a photon beam to the resultant absorbed dose distribution during single-turn rotating-beam therapy has been set up and solved for the case of a cylindrical phantom with the axis of rotation coinciding with the axis of symmetry of the cylinder. In the first approximation the results obtained are also valid when the axis of rotation is somewhat off-centred, even in a phantom that deviates from circular symmetry, provided the rotation is performed in both clockwise and counter clockwise directions. The calculated dose profiles indicate that improved dose uniformity can be achieved using a new type of non-linear wedge-shaped filter, which can easily be designed using the derived general analytic solution to the integral equation. (author)

Additional details

Publishing Information

Journal Title
Phys. Med. Biol.
Journal Volume
27
Journal Issue
10
Series
Phys. Med. Biol.
Journal Page Range
1221-1229
ISSN
0031-9155

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
14742494
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
FILTERS; INTEGRAL EQUATIONS; MATHEMATICAL MODELS; PHOTON BEAMS; RADIATION DOSES; RADIOTHERAPY; ROTATION; SPATIAL DOSE DISTRIBUTIONS
Descriptors DEC
BEAMS; DISTRIBUTION; EQUATIONS; MEDICINE; RADIATION DOSE DISTRIBUTIONS; SPATIAL DISTRIBUTION; THERAPY