Solution of an integral equation encountered in rotation therapy
Creators
- 1. Karolinska Sjukhuset, Stockholm (Sweden). Dept. of Hospital Physics
- 2. Stockholm Univ. (Sweden)
Description
An integral equation relating the lateral absorbed dose profile of a photon beam to the resultant absorbed dose distribution during single-turn rotating-beam therapy has been set up and solved for the case of a cylindrical phantom with the axis of rotation coinciding with the axis of symmetry of the cylinder. In the first approximation the results obtained are also valid when the axis of rotation is somewhat off-centred, even in a phantom that deviates from circular symmetry, provided the rotation is performed in both clockwise and counter clockwise directions. The calculated dose profiles indicate that improved dose uniformity can be achieved using a new type of non-linear wedge-shaped filter, which can easily be designed using the derived general analytic solution to the integral equation. (author)
Additional details
Publishing Information
- Journal Title
- Phys. Med. Biol.
- Journal Volume
- 27
- Journal Issue
- 10
- Series
- Phys. Med. Biol.
- Journal Page Range
- 1221-1229
- ISSN
- 0031-9155
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 14742494
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- FILTERS; INTEGRAL EQUATIONS; MATHEMATICAL MODELS; PHOTON BEAMS; RADIATION DOSES; RADIOTHERAPY; ROTATION; SPATIAL DOSE DISTRIBUTIONS
- Descriptors DEC
- BEAMS; DISTRIBUTION; EQUATIONS; MEDICINE; RADIATION DOSE DISTRIBUTIONS; SPATIAL DISTRIBUTION; THERAPY