Published 2010 | Version v1
Miscellaneous

The lube oil leakage from indicator valves of emergency diesel generator

  • 1. Hokuriku Electric Power Co., Inc., Shika Nuclear Power Station, Shika, Ishikawa (Japan)

Description

The lube oil leakage from indicator valves of Emergency Diesel Generator was found at Shika nuclear power plant Unit 2 in Dec. 2009. As a result of investigation, we found that temperature fall after shutdown of diesel engine generate negative pressure in the combustion chamber, and the cooling oil for piston leak into the combustion chamber through the oil-drain port of piston by this negative pressure. (author)

Part of:
Proceedings of the 7th annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
Nippon hozen gakkai dai-7-kai gakujutsu koenkai yoshishu

Publishing Information

Imprint Title
Proceedings of the 7th annual meeting of Japan Society of Maintenology
Imprint Pagination
623 p.
Journal Page Range
p. 167-170

Conference

Title
7. annual meeting of Japan Society of Maintenology
Dates
13-15 Jul 2010
Place
Omaezaki, Shizuoka (Japan)

Optional Information

Notes
7 figs. Imprint:Nippon hozen gakkai dai-7-kai gakujutsu koenkai yoshishu