Published February 1988 | Version v1
Report Restricted

Vertical viewing ECE diagnostic for the DIII-D tokamak

Description

The vertical viewing ECE diagnostic on DIII-D will be used to assess the non-thermal electron distributions resulting from ECRH and Electron Cyclotron Current Drive experiments. Electron cyclotron emission along a vertical chord is collected using an ellipsodal focusing mirror and retro-reflector (the latter to minimize wall reflections). The emission is then transported /approximately/20m using a quasi-optical transport system comprised of 8 lenses and 3 mirrors, and detected between the 2nd and the 10th harmonicas by a fast scanning (40 Hz) Michelson interferometer. The entire system has been aligned using a Gaussian beam simulator and absolutely calibrated, in-situ using a cold liquid nitrogen bath. Details of the design, installation, and calibration. 11 refs., 3 figs

Availability note (English)

Available from NTIS, PC A03/MF A01;1 as DE88010586.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
15 p.
Report number
GA-A--19174

Conference

Title
7. topical conference on high temperature plasma diagnostics.
Dates
13-17 Mar 1988.
Place
Napa, CA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19090538
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ECR HEATING; MICHELSON INTERFEROMETER; MIRRORS; PLASMA DIAGNOSTICS; SPECIFICATIONS; THERMONUCLEAR REACTORS; TOKAMAK DEVICES
Descriptors DEC
CLOSED PLASMA DEVICES; HEATING; HIGH-FREQUENCY HEATING; INTERFEROMETERS; MEASURING INSTRUMENTS; PLASMA HEATING; THERMONUCLEAR DEVICES

Optional Information