Published March 2016
| Version v1
Journal article
Near-infrared scintillation of liquid argon
- 1. Fermi National Accelerator Laboratory, Kirk Rd and Pine St., Batavia, IL 60510 (United States)
Description
Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 μm < λ < 1.5 μm). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab
Availability note (English)
Available from http://dx.doi.org/10.1088/1748-0221/11/03/C03010Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Instrumentation
- Journal Volume
- 11
- Journal Issue
- 03
- Journal Page Range
- p. C03010
- ISSN
- 1748-0221
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47073446
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ARGON; FERMILAB; LIQUEFIED GASES; NEAR INFRARED RADIATION; RADIATION DETECTORS; REVIEWS; SCINTILLATIONS; SPECTRA
- Descriptors DEC
- DOCUMENT TYPES; ELECTROMAGNETIC RADIATION; ELEMENTS; FLUIDS; GASES; INFRARED RADIATION; LIQUIDS; MEASURING INSTRUMENTS; NATIONAL ORGANIZATIONS; NONMETALS; RADIATIONS; RARE GASES; US DOE; US ORGANIZATIONS