Published November 15, 2002 | Version v1
Journal article

Inverse planning for interstitial gynecologic template brachytherapy: truly anatomy-based planning

Description

Purpose: Commercially available optimization schemes generally result in an undesirable dose distribution, because of the particular shapes of tumors extending laterally from the tandem. Dose distribution is therefore manually obtained by adjusting relative dwell time values until an acceptable solution is found. The objective of this work is to present the clinical application of an inverse planning dose optimization tool for the automatic determination of source dwell time values in the treatment of interstitial gynecologic templates. Methods and Materials: In cases where the tumor extends beyond the range of the tandem-ovoid applicator, catheters as well as the tandem are inserted into the paravaginal and parametrial region in an attempt to cover the tumor volume. CT scans of these patients are then used for CT-based dose planning. Dose distribution is obtained manually by varying the relative dwell times until adequate dose coverage is achieved. This manual planning is performed by an experienced physician. In parallel, our in-house inverse planning based on simulated annealing is used to automatically determine which of all possible dwell positions will become active and to calculate the dwell time values needed to fulfill dose constraints applied to the tumor volume and to each organ at risk. To compare the results of these planning methods, dose-volume histograms and isodose distributions were generated for the target and each organ at risk. Results: This procedure has been applied for the dose planning of 12 consecutive interstitial gynecologic templates cases. For all cases, once the anatomy was contoured, the routine of inverse planning based on simulated annealing found the solution to the dose constraints within 1 min of CPU time. In comparison, manual planning took more than 45 min. The inverse planning-generated plans showed improved protection to organs at risk for the same coverage compared to manual planning. Conclusion: This inverse planning tool reduced the planning time significantly and produced improved plans with reduced dose to the organs at risk. Furthermore, the inverse planning approach improves the physician's control over treatment. The focus becomes the physician's prescription to the target and his or her compromise due to dose to normal structures

Additional details

Identifiers

PII
S0360301602038026;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
54
Journal Issue
4
Journal Page Range
p. 1243-1251
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34012631
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DOSE LIMITS; FEMALE GENITALS; INTERNAL IRRADIATION; PLANNING; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS
Descriptors DEC
BODY; IRRADIATION; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATION DOSE DISTRIBUTIONS; RADIOLOGY; SAFETY STANDARDS; STANDARDS; THERAPY

Optional Information

Copyright
Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.