Published 1989
| Version v1
Book
Electron spectral contribution of prompt-response self-powered neutron detectors
Creators
- 1. LNETI - Institute of Nuclear Sciences and Engineering, 2686 Sacavem (Portugal)
Description
In the present work the authors use a new model for calculating the effective charge induced per neutron capture in a prompt-response Self-Powered Neutron Detector (SPND). This charge is written as the integral over all possible energies of the spectral function S(E) weighted with the electron spectral contribution ε(E). For the latter function, which has a clear physical meaning, they derive an analytical expression through the path-length distribution function n(κ). This relation holds for both finite and infinite length emitters. The method is used to calculate the dependence of the effective charge with the geometry of the detector
Additional details
Publishing Information
- Publisher
- ASTM.
- Imprint Place
- Philadelphia, PA (USA)
- ISBN
- 0-8031-1184-3
- Imprint Title
- Reactor dosimetry
- Imprint Pagination
- 798 p.
- Series
- STP 1001.
- Journal Page Range
- p. 734-741.
Conference
- Title
- methods, applications, and standardization.
- Acronym
- 6. ASTM-Euratom symposium on reactor dosimetry
- Dates
- 31 May - 5 Jun 1987.
- Place
- Jackson Hole, WY (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 21037018
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALGORITHMS; DISTRIBUTION FUNCTIONS; ELECTRON SPECTRA; ENERGY SPECTRA; GEOMETRY; SELF-POWERED NEUTRON DETECTORS
- Descriptors DEC
- MATHEMATICS; MEASURING INSTRUMENTS; NEUTRON DETECTORS; RADIATION DETECTORS; SELF-POWERED DETECTORS; SPECTRA
Optional Information
- Secondary number(s)
- CONF-870501--.