Published 2004
| Version v1
Miscellaneous
The regime map for the direct contact condensation of steam vertically injected through a mini nozzle
Creators
- 1. Pohang Univ. of Science and Technology, Pohang (Korea, Republic of)
- 2. Korea Institute of Science and Technology Evaluation and Planning, Seoul (Korea, Republic of)
Description
Steam was vertically discharged into water through mini nozzles of various diameters (d=0.115, 0.520, 1.55mm). The condensation was observed and categorized into several types of condensation regimes for each of the nozzles. Compared with the regimes in the previous researches, the regimes of 'internal necking with attached bubble' and 'internal chug with detached bubble' were newly observed. Depending on a nozzle, some regimes expanded, shrank, or moved in the regime map. For the nozzle of 1.55mm, the regime map was similar to Chan and Lee (1982) except that the regime of 'internal chug' was not observed. For the nozzle of 0.115mm, the regime of 'internal chug' appeared even at high pool temperature
Additional details
Publishing Information
- Publisher
- KSME
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the KSME 2004 fall annual meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [5 p.]
Conference
- Title
- KSME 2004 fall annual meeting
- Dates
- 3-5 Nov 2004
- Place
- Taejon (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36017413
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BUBBLES; CALIBRATION; CAMERAS; FLOW RATE; FLOW VISUALIZATION; MAPPING; NOZZLES; STEAM; VAPOR CONDENSATION
Optional Information
- Notes
- 5 refs, 8 figs, 1 tab