The maintenance optimization of structural components in nuclear power plants
Creators
- 1. Electricite de France, 78 - Chatou (France). Direction des Etudes et Recherches
- 2. Electricite de France, 92 - Paris la Defense (France). Direction EDF Production Transport
Description
An optimization process, called 'OMF-Structures', is developed by Electricite de France (EDF) in order to extend the current 'OMF' Reliability Centered Maintenance to piping structural components. The Auxiliary Feedwater System of a 900 MW French nuclear plant has been studied in order to lay the foundations of the method. This paper presents the currently proposed principles of the process. The principles of the OMF-Structures process include 'Risk-Based Inspection' concepts within an RCM process. Two main phases are identified: The purpose of the first phase is to select the risk-significant failure modes and associated elements. This phase consists of two major steps: potential consequences evaluation and reliability performance evaluation. The second phase consists of the definition of preventive maintenance programs for piping elements that are associated with risk-significant failure modes. (author)
Availability note (English)
Available from INIS in electronic formFiles
30001860.pdf
Files
(640.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:5b90d7336d64b0ae8eaf5920d1748396
|
640.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- [14 p.]
- Report number
- EDF--98-NB-00009
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 30001860
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- NUCLEAR POWER PLANTS; OPTIMIZATION; PWR TYPE REACTORS; REACTOR MAINTENANCE; RELIABILITY; RISK ASSESSMENT; SYSTEM FAILURE ANALYSIS
- Descriptors DEC
- ENRICHED URANIUM REACTORS; MAINTENANCE; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTORS; SYSTEMS ANALYSIS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 8 refs.