Published November 1978 | Version v1
Journal article

Patient dosage in computed tomography

  • 1. Mayo Clinic/Foundation, Rochester, MN

Description

The maximum surface dosage in most clinical CT scans seems to range from 2 to 10 rads/study but much larger dose per study values seem possible with both rotate-translate and rotary geometry designs. The CT scanner type in itself does not significantly reduce doses. Secondary radiation dose values were measured for critical organs and indicate that dosage from secondary radiations may be reduced significantly by external shielding. Dose values in the vicinity of most CT scanners are typically 1 to 2 mrad/scan at 1 meter at the parameters of a typical clinical scan

Additional details

Publishing Information

Journal Title
Radiology
Journal Volume
129
Journal Issue
2
Series
Radiology.
Journal Page Range
457-463

Conference

Title
62. scientific assembly and annual meeting of the Radiological Society of North America.
Dates
14 Nov 1976.
Place
Chicago, IL, USA.