Effect of computed tomography noise and tissue heterogeneity on cerebral blood flow determination by xenon-enhanced computed tomography
Description
The errors associated with derivation of cerebral blood flow values by the xenon-enhanced computed tomography (CT) method have been evaluated as a function of tissue heterogeneity and CT noise. The results of this study indicate that CT noise introduces large errors in the derived flow value when data for a single, unprocessed voxel are used for this purpose. CT noise increases the derived flow values in a systematic way. Tissue heterogeneity results in a systematic error which lowers the derived flow values. Errors due to both parameters are computed for typical and extreme conditions
Additional details
Publishing Information
- Journal Title
- Med. Phys.
- Journal Volume
- 14
- Journal Issue
- 4
- Series
- Med. Phys.
- Journal Page Range
- 557-561
- ISSN
- 0094-2405
- CODEN
- MPHYA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19018292
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD FLOW; BRAIN; EMISSION COMPUTED TOMOGRAPHY; ERRORS; XENON ISOTOPES
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; NERVOUS SYSTEM; ORGANS; TOMOGRAPHY