Published November 2010 | Version v1
Report Restricted

Results from a prototype chicane-based energy spectrometer for a linear collider

  • 1. London Univ., Egham (United Kingdom). Royal Holloway
  • 2. Univ. College London (United Kingdom)
  • 3. Deutsches Electronen Synchrotron DESY, Zeuthen (Germany)
  • 4. Deutsches Electronen Synchrotron DESY, Hamburg (Germany)

Description

The International Linear Collider (ILC) and other proposed high energy e+e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10-4. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 . 10-4 was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance. (orig.)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
18 p.
ISSN
0418-9833
Report number
DESY--10-146

Optional Information

Secondary number(s)
SLAC-PUB--14255