Measuring muscle quality: associations between echo intensity and normalized strength and power

  • 1. Neuromuscular Assessment Laboratory, Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, Chapel Hill, NC (United States)
  • 2. Department of Human Movement Sciences, Old Dominion University, Norfolk, VA (United States)
  • 3. Department of Kinesiology, University of Alabama, Tuscaloosa, AL (United States)

Description

Objective. Muscle quality has received considerable attention within the literature due to its influence on health and performance. However, it has been assessed by various measures (e.g. ultrasound imaging, normalized strength), contributing to a lack of a consensus definition. The purpose of this study was to investigate the association between common muscle quality measures: vastus lateralis echo intensity (EI) and peak torque (PT) and power (PP) normalized to thigh lean mass (TLM) and thigh fat mass (TFM). Approach. Participants' (n = 39; age = 32.7 ± 8.2 years; %BF = 24.1% ±8.1%) whole body and leg composition was assessed via dual-energy x-ray absorptiometry and custom thigh analyses. Subcutaneous fat-corrected muscle EI was assessed via ultrasonography. Maximal PT and PP of the dominant leg extensors were examined on a calibrated dynamometer and were normalized to both TLM and TFM, respectively. Pearson product-moment correlations were used to examine the associations between EI and PT/TLM, PT/TFM, PP/TLM, and PP/TFM. Main results. Greater muscle EI was significantly related with lower PT/TFM and PP/TFM (r = −0.74 to −0.70, P < 0.001), but unrelated to PT/TLM or PP/TLM (P ≥ 0.205). Significance. These findings suggest that ultrasound imaging (muscle EI) and normalized strength and power may not be used interchangeably to define muscle quality, and muscle EI may be more sensitive to the adiposity of the limb than TLM. Future research should consider using separate and consistent definitions when referring to imaging-derived or normalized strength and power values of muscle quality. (note)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6579/abea24

Additional details

Identifiers

Publishing Information

Journal Title
Physiological Measurement (Print)
Journal Volume
42
Journal Issue
3
Journal Page Range
[6 p.]
ISSN
0967-3334

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
53066033
Subject category
S60: APPLIED LIFE SCIENCES;
Descriptors DEI
FATS; LEGS; MASS; MUSCLES; ULTRASONOGRAPHY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; LIMBS