Published November 1988
| Version v1
Report
Open
10 channel grating polychromator for the measurements of electron cyclotron emission
Description
A 10-channel grating polychromator has been developed and applied for the measurements of the second harmonic electron cyclotron emission from the JIPP T-IIU tokamak plasma. The frequency resolution measured at 150 GHz is about 3 GHz which corresponds to the spatial resolution of 1.8 cm near the center of the plasma column. The grating efficiency is about 80 % for S-polarization around 160 GHz. Its excellent time resolution, Δt ≤ 2 μs, is favorable for studying MHD activities in hot plasmas. It has been found from the measurements in JIPP T-IIU that the grating polychromator is a powerful diagnostic tool for the measurements of electron temperature of the plasma. (author)
Availability note (English)
MF available from INIS under the Report Number.Files
20031280.pdf
Files
(374.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:8000b94889f05f5bbc4883be23779a99
|
374.2 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 32 p.
- Report number
- IPPJ--893
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 20031280
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- DIFFRACTION GRATINGS; ELECTRON CYCLOTRON-RESONANCE; ELECTRON TEMPERATURE; JIPPT-2 DEVICE; MICROWAVE RADIATION; PHOTON EMISSION; PLASMA DIAGNOSTICS; SPECTROMETERS
- Descriptors DEC
- CLOSED PLASMA DEVICES; CYCLOTRON RESONANCE; ELECTROMAGNETIC RADIATION; EMISSION; MEASURING INSTRUMENTS; RADIATIONS; RESONANCE; STELLARATORS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES