Highly efficient pulsed power supply system with a two-stage LC generator and a step-up transformer for fast capillary discharge soft x-ray laser at shorter wavelength
Creators
- 1. Department of Energy Sciences, Tokyo Institute of Technology, 4259-J2-35, Nagatsuta, Midori-ku, Yokohama 226-8502 (Japan)
Description
Highly efficient and compact pulsed power supply system for a capillary discharge soft x-ray laser (SXRL) has been developed. The system consists of a 2.2 μF two-stage LC inversion generator, a 2:54 step-up transformer, a 3 nF water capacitor, and a discharge section with a few tens of centimeter length capillary. Adoption of the pulsed transformer in combination with the LC inversion generator enables us to use only one gap switch in the circuit for charging the water capacitor up to about 0.5 MV. Furthermore, step-up ratio of a water capacitor voltage to a LC inversion generator initial charging voltage is about 40 with energy transfer efficiency of about 50%. It also leads to good reproducibility of a capillary discharge which is necessary for lasing a SXRL stably. For the study of the possibility of lasing a SXRL at shorter wavelength in a small laboratory scale, high-density and high-temperature plasma column suitable for the laser can be generated relatively easily with this system.
Additional details
Identifiers
- DOI
- 10.1063/1.3276705;
Publishing Information
- Journal Title
- Review of Scientific Instruments
- Journal Volume
- 81
- Journal Issue
- 1
- Journal Page Range
- p. 013303-013303.3
- ISSN
- 0034-6748
- CODEN
- RSINAK
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44013575
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CAPACITORS; CAPILLARIES; EFFICIENCY; ELECTRIC GENERATORS; ELECTRIC POTENTIAL; ENERGY TRANSFER; HOT PLASMA; PLASMA DENSITY; POWER SUPPLIES; SOFT X RADIATION; SWITCHES; TRANSFORMERS; WATER; X-RAY LASERS
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; ELECTRICAL EQUIPMENT; ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; EQUIPMENT; HYDROGEN COMPOUNDS; IONIZING RADIATIONS; LASERS; ORGANS; OXYGEN COMPOUNDS; PLASMA; RADIATIONS; X RADIATION
Optional Information
- Notes
- (c) 2010 American Institute of Physics