Causes of instability at LaSalle and consequences from postulated scram failure

Description

The March 9, 1988 instability event at the LaSalle County-2 BWR power plant was simulated on the BNL Engineering Plant Analyzer (EPA) in order to assess its ability to simulate oscillatory transients, to identify the causes of the instability, to determine the maximum power amplitude of limit-cycle oscillations after postulated scram failure and to rank leading modeling parameters which affect instability. The EPA was found capable of simulating the LaSalle instability, which was found to have been caused by the combination of low core flow, moderately high power, low feedwater temperature and strong bottom power peaking. After postulated scram failure, the power was found to peak at 1300% of normal full power. Void reactivity, power peaking and core exit flow impedance were found to be the leading phenomena affecting thermohydraulic instability. 3 refs. 17 figs., 3 tabs

Availability note (English)

MF available from INIS under the Report Number; NTIS, PC A03/MF A01 as DE91004011; OSTI; INIS; US Govt. Printing Office Dep.

Files

22023292.pdf

Files (381.3 kB)

Name Size Download all
md5:9e8403539fbf3786dfacdfb8f6ef8b95
381.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
BNL-NUREG--45273

Conference

Title
International workshop on boiling water reactor stability.
Dates
17-19 Oct 1990.
Place
Upton, NY (USA).

Optional Information

Contract/Grant/Project number
Contract AC02-76CH00016
Secondary number(s)