Published 1976
| Version v1
Book
Performance testing of primary coolant purification plant
Description
The primary coolant circuit water treatment plant of units III and IV of the Novovoronezh nuclear power plant consists of two filters designed for full pressure coolant cleaning. The design filter media of the plant filters, operating results and modifications in the composition of the filter media based on the results are shown. (F.M.)
Additional details
Additional titles
- Original title (Czech)
- Vyzkum provoznich charakteristik prace cistici stanice primarniho chladiva
Publishing Information
- Publisher
- Czechoslovak Atomic Energy Commission.
- Imprint Place
- Prague
- Imprint Title
- Operation experience of the Novovoronezh nuclear power plant
- Journal Page Range
- p. 113-117.
INIS
- Country of Publication
- Serbia and Montenegro
- Country of Input or Organization
- Serbia and Montenegro
- INIS RN
- 9368154
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CLEANING; DECONTAMINATION; EFFICIENCY; FILTERS; ION EXCHANGE MATERIALS; PRIMARY COOLANT CIRCUITS; RESINS; WATER; WATER CHEMISTRY; WWER-3 REACTOR; WWER-4 REACTOR
- Descriptors DEC
- CHEMISTRY; COOLING SYSTEMS; ENRICHED URANIUM REACTORS; HYDROGEN COMPOUNDS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; OXYGEN COMPOUNDS; POLYMERS; POWER REACTORS; PWR TYPE REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS
Optional Information
- Notes
- Imprint:Translated from Russian.;Zkusenosti z provozu Novovoronezske jaderne elektrarny.