Published December 12, 2015 | Version v1
Journal article

Role of 3T multiparametric-MRI with BOLD hypoxia imaging for diagnosis and post therapy response evaluation of postoperative recurrent cervical cancers

  • 1. Department of Imaging Sciences and Biomedical Engineering, Kings College London (United Kingdom)
  • 2. Department of Radiodiagnosis and Imaging, Tata Memorial Centre, Mumbai 400012 (India)
  • 3. Department of Radiation-Oncology, Tata Memorial Centre, Mumbai 400012 (India)

Description

•In operated cervix cancer, the accuracy of diagnosing vaginal vault/local recurrent lesions was higher at combined multiparametric MR imaging and conventional MR imaging (100%) than at conventional MR imaging (70%) or multiparametric MR imaging (96.7%) alone.•We found a significant correlation between percentage tumor regression and pre-treatment parameters: NEI (p = 0.02), the maximum slope (p = 0.04), mADC value (p = 0.001) and amount of hypoxic fraction present in the pretherapy MRI (p = 0.01).•Multiparametric and BOLD hypoxia MR Imaging are feasible and reliable in diagnosing post-operative recurrence in cervical cancer and should be applied when there is clinical suspicion of post-operative recurrence.•Quantitative image features obtained at multiparametric-MRI with BOLD hypoxia imaging has potential to be an appropriate and reliable biologic target for radiation dose painting to optimize therapy in future. In operated cervix cancer, the accuracy of diagnosing vaginal vault/local recurrent lesions was higher at combined multiparametric MR imaging and conventional MR imaging (100%) than at conventional MR imaging (70%) or multiparametric MR imaging (96.7%) alone. We found a significant correlation between percentage tumor regression and pre-treatment parameters: NEI (p = 0.02), the maximum slope (p = 0.04), mADC value (p = 0.001) and amount of hypoxic fraction present in the pretherapy MRI (p = 0.01). Multiparametric and BOLD hypoxia MR Imaging are feasible and reliable in diagnosing post-operative recurrence in cervical cancer and should be applied when there is clinical suspicion of post-operative recurrence. Quantitative image features obtained at multiparametric-MRI with BOLD hypoxia imaging has potential to be an appropriate and reliable biologic target for radiation dose painting to optimize therapy in future. To assess the diagnostic value of multiparametric-MRI (MPMRI) with hypoxia imaging as a functional marker for characterizing and detecting vaginal vault/local recurrence following primary surgery for cervical cancer. With institutional review board approval and written informed consent 30 women (median age: 45 years) from October 2009 to March 2010 with previous operated carcinoma cervix and suspected clinical vaginal vault/local recurrence were examined with 3.0T-MRI. MRI imaging included conventional and MPMRI sequences [dynamic contrast enhanced (DCE), diffusion weighted (DW), 1H-MR spectroscopy (1HMRS), blood oxygen level dependent hypoxia imaging (BOLD)]. Two radiologists, blinded to pathologic findings, independently assessed the pretherapy MRI findings and then correlated it with histopathology findings. Sensitivity, specificity, positive predictive value, negative predictive value and their confidence intervals were calculated. The pre and post therapy conventional and MPMRI parameters were analyzed and correlated with response to therapy. Of the 30 patients, there were 24 recurrent tumors and 6 benign lesions. The accuracy of diagnosing recurrent vault lesions was highest at combined MPMRI and conventional MRI (100%) than at conventional-MRI (70%) or MPMRI (96.7%) alone. Significant correlation was seen between percentage tumor regression and pre-treatment parameters such as negative enhancement integral (NEI) (p = 0.02), the maximum slope (p = 0.04), mADC value (p = 0.001) and amount of hypoxic fraction on the pretherapy MRI (p = 0.01). Conventional-MR with MPMRI significantly increases the diagnostic accuracy for suspected vaginal vault/local recurrence. Post therapy serial MPMRI with hypoxia imaging follow-up objectively documents the response. MPMRI and BOLD hypoxia imaging provide information regarding tumor biology at the molecular, subcellular, cellular and tissue levels and this information may be used as an appropriate and reliable biologic target for radiation dose painting to optimize therapy in future

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejro.2015.11.003; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4811859

Additional details

Publishing Information

Journal Title
European Journal of Radiology Open
Journal Volume
3
Journal Page Range
p. 22-30
ISSN
2352-0477

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47117602
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ANIMAL TISSUES; ANOXIA; BIOMEDICAL RADIOGRAPHY; CARCINOMAS; CORRELATIONS; DIAGNOSIS; DIFFUSION; IMAGES; ITERATIVE METHODS; MAGNETIC RESONANCE; NMR IMAGING; PROTON DENSITY; RADIATION DOSES; RADIOTHERAPY
Descriptors DEC
BODY; CALCULATION METHODS; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; RADIOLOGY; RESONANCE; THERAPY

Optional Information

Copyright
Copyright (c) 2015 Published by Elsevier Ltd.
Notes
PMCID: PMC4811859; PMID: 27069975; PUBLISHER-ID: S2352-0477(15)30009-5; OAI: oai:pubmedcentral.nih.gov:4811859; This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).