Modular drag disc turbine qualification tests

Description

Qualification Tests were performed on three modular drag-disc turbines (MDTT) at ARA III under the direction of C.E. Winsel. The tests were performed on MDTTs that had been rejected by the Quality Division (Quality Division Reports were issued) due to the sensitivity range and accepted as is by the Project Engineer. These tests consisted of full flow calibration and vibration tests. The results of these tests indicate the MDTT will survive 7.5g peak loading below 1400 Hz and should not be subjected to g loading for extended periods of time between 1400 and 1450 Hz

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
EGG/LTR--141-109