A Compton suppression high resolution spectrometer for low level radioactivity measurements
- 1. Universitat de Valencia (Spain)
- 2. Universidad de Extremadura Caceres (Spain)
Description
In radio environmental measurements performed by high resolution γ-ray spectroscopy with Ge(Hp) there is a significant background as a result of incomplete energy deposition of incident photons undergoing Compton scattering in the germanium detector. In consequence, photons with certain energy introduce at lower energies a Compton continuum that increases the limit of detection for other radionuclides in the sample. This Compton continuum can be reduced by surrounding the Ge(Hp) detector with a second detector, usually made of NaI(T1) or BGO. The guard detects Compton scattered radiation occurred in the main detector, and these events are rejected from the final spectrum by means of a coincidence condition through an appropriate electronic circuit. The Laboratory of Environmental Radioactivity at the University of Valencia and the Laboratory of Environmental Radioactivity of the Physics Department at the Veterinary School of Caceres, UEx, have designed, assembled and adjusted a detection system for high resolution gamma-ray spectroscopy with Compton effect suppression. The purpose of the design has been the optimising of the limit of detection and the measuring time for radionuclides with representative photopeak between 300 keV and 900keV. This has been achieved by simplifying the instrumentation and at a reasonable cost. (Author)
Additional details
Additional titles
- Original title (Spanish)
- Espectrometro gamma de alta resolucion con supresion de efecto compton para medidas de radiactividad ambiental
Publishing Information
- Publisher
- Senda Editorial
- Imprint Place
- Madrid (Spain)
- Imprint Title
- 24 Annual meeting of the Spanish Nuclear Society, Valladolid 14-16 October 1998
- Imprint Pagination
- 1977 p.
- Journal Page Range
- p. 27-39
INIS
- Country of Publication
- Spain
- Country of Input or Organization
- Spain
- INIS RN
- 29066471
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- COMPTON EFFECT; ENVIRONMENT; GAMMA SPECTROMETERS; GE SEMICONDUCTOR DETECTORS; RADIONUCLIDE MIGRATION; SPAIN
- Descriptors DEC
- BASIC INTERACTIONS; DEVELOPING COUNTRIES; ELASTIC SCATTERING; ELECTROMAGNETIC INTERACTIONS; ENVIRONMENTAL TRANSPORT; EUROPE; INTERACTIONS; MASS TRANSFER; MEASURING INSTRUMENTS; RADIATION DETECTORS; SCATTERING; SEMICONDUCTOR DETECTORS; SPECTROMETERS; WESTERN EUROPE
Optional Information
- Notes
- Imprint:24 Reunion anual de la Sociedad Nuclear Espanola, Valladolid 14-16 Octubre 1998