Published February 2007 | Version v1
Journal article

Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems

  • 1. University Medical Center of Hamburg-Eppendorf, Clinic of Diagnostic and Interventional Radiology, Hamburg (Germany)
  • 2. University Hospital of Freiburg, Department of Oral and Maxillofacial Surgery, Freiburg (Germany)
  • 3. University Medical Center of Hamburg-Eppendorf, Department of Orthodontics, Hamburg (Germany)

Description

The objective of this paper is to evaluate magnetic field interactions at 1.5 and 3 T for 20 orthodontic devices used for fixed orthodontic therapy. Twenty springs and auxiliary parts made from varying ferromagnetic alloys were tested for magnetic field interactions in the static magnetic field at 1.5 and 3 T. Magnetic translational force Fz (in millinewtons) was evaluated by determining the deflection angle β [American Society for Testing and Materials (ASTM standard test method)]. Magnetic-field-induced rotational force Frot was qualitatively determined using a five-point scale. β was found to be >45 in 13(15) devices at 1.5(3) T and translational force Fz exceeded gravitational force Fg on the particular object [Fz 10.17-261.4 mN (10.72-566.4 mN) at 1.5(3) T]. Fz was found to be up to 24.1(47.5)-fold higher than Fg at 1.5(3) T. Corresponding to this, Frot on the objects was shown to be high at both field strengths (≥ +3). Three objects (at 1.5 T) and one object (at 3 T) showed deflection angles <45 , but Frot was found to be ≥ +3 at both field strengths. For the remaining objects, β was below 45 and torque measurements ranged from 0 to +2. Of 20 objects investigated for magnetic field interactions at 1.5(3) T, 13(15) were unsafe in magnetic resonance (MR), based on the ASTM criteria of Fz. The implications of these results for orthodontic patients undergoing MRI are discussed. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-006-0335-x

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
17
Journal Issue
2
Journal Page Range
p. 533-540
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
38044134
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DENTISTRY; DIAGNOSIS; JAW; NMR IMAGING; TEETH
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; MEDICINE; ORAL CAVITY; ORGANS; SKELETON; SKULL