New developments for 3D CT at high X-ray energy
Creators
- 1. Eidgenoessische Materialpruefungs- und Forschungsanstalt (EMPA), Duebendorf (Switzerland)
- 2. Bologna Univ. (Italy). Dept. of Physics
- 3. RayScan Technologies, Meersburg (Germany)
Description
CT is well suited both for measurements and for flaw detection in cast metal products which as a rule have a complex shape and internal caverns. Currently available tomographs for 3D scanning of large objects still have shortcomings. Line detectors - normally operated with a 450 kV X-ray source - are slow. Systems with detector panels normally have 225 kV microfocus tubes which provide insufficient power. The microfocus tube cannot be replaced by a 450 kV tube as scattered radiation at higher energies will considerably reduce the image quality of the tomograms. In the context of European research projects during the past few years, Empa developed new methods for faster data acquisition with line detector systems and correction of scattered radiation for CT with conical beams and with panel detectors. The contribution outlines the state of the art and also presents new trends, especially for fast 3D volume scanning with high X-ray energy
Abstract (German)
Fuer Gussprodukte, welche in der Regel komplexe Formen mit Hohlraeumen aufweisen, ist die Computertomografie (CT) sowohl fuer Messaufgaben wie auch fuer die Detektion von Fehlern hervorragend geeignet. Allerdings weisen die heute auf dem Markt verfuegbaren Tomografen fuer die 3D-Datenerfassung groesserer Pruefobjekte noch immer wesentliche Nachteile auf. Im Falle von Zeilendetektorsystemen, die in der Regel mit einer 450 kV Industrie-Roentgenroehre betrieben werden, ist der Scanvorgang schichtweise und daher langsam. Bei Geraeten mit Flaechendetektoren reicht die Durchstrahlungsleistung der bei diesen Systemen ueblicherweise verwendeten 225 kV Mikrofokusroehren nicht aus. Die Mikrofokusroehre kann nicht ohne weiteres durch eine 450 kV Roehre ersetzt werden, da bei hohen Energien im Pruefobjekt ein hoher Anteil an Streustrahlung entsteht, welche die Bildqualitaet der Tomogramme wesentlich reduziert. Die Empa hat in den vergangenen Jahren im Rahmen von europaeischen Forschungsprojekten neue Verfahren zur Beschleunigung der Datenerfassung von Zeilendetektorsystemen und der Korrektur von Streustrahlung fuer Kegelstrahl-CT mit Flaechendetektoren entwickelt. Der Beitrag gibt einen Ueberblick ueber den Stand der Technik und zeigt neue Entwicklungen insbesondere zur schnellen 3D-Volumenerfassung mit hoher RoentgenenergieAdditional details
Additional titles
- Original title (German)
- Neue Entwicklungen fuer 3D-CT bei hoher Roentgenenergie
Publishing Information
- ISBN
- 978-3-940283-09-2
- Imprint Title
- 2008 annual meeting of the Deutsche Gesellschaft fuer Zerstoerungsfreie Pruefung (DGZfP): NDE in research, development and application
- Imprint Pagination
- 873 p.
- Journal Volume
- 113-CD
- Series
- Deutsche Gesellschaft fuer Zerstoerungsfreie Pruefung. Berichtsband
- Journal Page Range
- 7 p.
Conference
- Title
- NDE in research, development and application
- Original Conference Title
- Jahrestagung 2008 der Deutschen Gesellschaft fuer Zerstoerungsfreie Pruefung e.V. (DGZfP): ZfP in Forschung, Entwicklung und Anwendung
- Acronym
- 2008 annual meeting of the Deutsche Gesellschaft fuer Zerstoerungsfreie Pruefung (DGZfP)
- Dates
- 28-30 Apr 2008
- Place
- St. Gallen (Switzerland)
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 40015902
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CASTINGS; COMPUTERIZED TOMOGRAPHY; SCATTERING; X-RAY DETECTION; X-RAY TUBES
- Descriptors DEC
- DETECTION; DIAGNOSTIC TECHNIQUES; ELECTRON TUBES; EQUIPMENT; RADIATION DETECTION; TOMOGRAPHY; X-RAY EQUIPMENT
Optional Information
- Notes
- 6 refs. Imprint:DGZfP-Jahrestagung 2008. Zerstoerungsfreie Materialpruefung. ZfP in Forschung, Entwicklung und Anwendung