Published 1996 | Version v1
Journal article

The use of passive detectors to monitor tritium on surfaces

  • 1. Oak Ridge National Lab., TN (United States)

Description

Commercially available BeO exoelectron dosemeters and electret ion chambers (EICs) are being adapted and applied to in situ field monitoring of tritium on surfaces. Thin layer BeO on a conductive graphite substrate is of the order of 50 times more sensitive to tritium than the EIC. At the US department of Energy release limit for fixed surface tritium of 5000 dpm per 100 cm2, the exposure time for quantification with the exoelectron dosemeter is of the order of one hour. A multipoint Geiger counter was used for reading exoelectron emission. An alternative ceramic BeO dosemeter (Thermalox 995) has low electrical conductivity and will require a different reader to overcome problems of surface charging during exoemission. The electret is very easy to use and read. Its practical use will be for surfaces with relatively high levels of tritium contamination. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
65
Journal Issue
1-4
Journal Page Range
p. 385-388.
ISSN
0144-8420
CODEN
RPDODE

Conference

Title
11. international conference on solid state dosimetry.
Dates
10-14 Jul 1995.
Place
Budapest (Hungary).

Optional Information

Secondary number(s)
CONF--950708.