Published January 23, 2008 | Version v1
Report

Design and Performance of the LCLS Cavity BPM System

Description

In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM010 monopole reference cavity and a TM110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results

Availability note (English)

Available from http://www.slac.stanford.edu/cgi-wrap/getdoc/slac-pub-13067.pdf; http://www.slac.stanford.edu/cgi-wrap/pubpage?slac-pub-13067.html; PURL: https://www.osti.gov/servlets/purl/922592-3B7nR4/

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
SLAC-PUB--13067

Conference

Title
Particle Accelerator Conference (PAC 07)
Dates
25-29 Jun 2007
Place
Albuquerque, NM (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
39025864
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
A CENTERS; ACCELERATORS; BEAM POSITION; DESIGN; DIPOLES; HETERODYNE RECEIVERS; MONITORS; MONOPOLES; PERFORMANCE; PROCESSING; SPECIFICATIONS
Descriptors DEC
COLOR CENTERS; CRYSTAL DEFECTS; CRYSTAL STRUCTURE; ELECTRONIC EQUIPMENT; EQUIPMENT; MEASURING INSTRUMENTS; MICROWAVE EQUIPMENT; MULTIPOLES; POINT DEFECTS; RADIO EQUIPMENT; VACANCIES

Optional Information

Contract/Grant/Project number
AC02-76SF00515
Notes
Conf.Proc.C070625:4366,2007
Funding organization
US Department of Energy (United States)