Published January 23, 2008
| Version v1
Report
Design and Performance of the LCLS Cavity BPM System
Description
In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM010 monopole reference cavity and a TM110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results
Availability note (English)
Available from http://www.slac.stanford.edu/cgi-wrap/getdoc/slac-pub-13067.pdf; http://www.slac.stanford.edu/cgi-wrap/pubpage?slac-pub-13067.html; PURL: https://www.osti.gov/servlets/purl/922592-3B7nR4/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- SLAC-PUB--13067
Conference
- Title
- Particle Accelerator Conference (PAC 07)
- Dates
- 25-29 Jun 2007
- Place
- Albuquerque, NM (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 39025864
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- A CENTERS; ACCELERATORS; BEAM POSITION; DESIGN; DIPOLES; HETERODYNE RECEIVERS; MONITORS; MONOPOLES; PERFORMANCE; PROCESSING; SPECIFICATIONS
- Descriptors DEC
- COLOR CENTERS; CRYSTAL DEFECTS; CRYSTAL STRUCTURE; ELECTRONIC EQUIPMENT; EQUIPMENT; MEASURING INSTRUMENTS; MICROWAVE EQUIPMENT; MULTIPOLES; POINT DEFECTS; RADIO EQUIPMENT; VACANCIES
Optional Information
- Contract/Grant/Project number
- AC02-76SF00515
- Notes
- Conf.Proc.C070625:4366,2007
- Funding organization
- US Department of Energy (United States)