Published 1976 | Version v1
Journal article

Geophysical applicability of aerosol size distribution measurements using cascade impactors and proton induced X-ray emission

  • 1. Florida State Univ., Tallahassee (USA)

Description

Proton Induced X-ray Emission, (PIXE), is capable of high precision analysis for trace element components of aerosol particle size fractions sampled by cascade impactor. A statistical evaluation of data quality has been carried out in order to distinguish between analytical uncertainties in the PIXE procedure, errors caused by cascade impactor performance and by other factors in the sampling procedure, and geophysical causes of differences in composition and particle size distributions of the elements in aerosols. Replicate analyses and simultaneous samplings taken in north Florida and St. Louis have been used for the data evaluation. In addition to the analytical error the sampling procedure contributes an error of approximately 10% to be added quadratically. The resulting precision is sufficient to evaluate the data in geophysical terms. This is illustrated by means of sample sets taken simultaneously in an urban, forest and coastal environment of the same region. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Atmospheric Environment (1967)
Journal Volume
10
Journal Issue
8
Series
Atmos. Environ.
Journal Page Range
571-576
ISSN
0004-6981

INIS

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent