Published April 1998 | Version v1
Journal article

Lifetime of charge stripping foils and transmission of heavy ions in 12UD-pelletron tandem accelerator

  • 1. Tsukuba Univ., Sakura, Ibaraki (Japan). Tandem Accelerator Center
  • 2. High Energy Accelerator Research Organization, Tanashi Branch, Tanashi, 188 Tokyo (Japan)

Description

The lifetime of charge stripping foils produced by means of new arc-discharge method developed by Sugai was measured for the bombardment of 10 MeV Au ions. Transmission of Au ions through 12UD-pelletron tandem accelerator was also measured. The lifetime of tested charge stripping foils for 10-15 μg/cm2 thick and 3.8-5.0 μg/cm2 thick, respectively, demonstrated to be longer than that of usual arc-discharge method by more than 30 times and 20 times, meanwhile, the transmission of 3.8-5.0 μg/cm2 thick foils was about 4 times higher than that of 10-15 μg/cm2 thick foils. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms
Journal Volume
139
Journal Issue
1-4
Journal Page Range
p. 451-455
ISSN
0168-583X
CODEN
NIMBEU

Conference

Title
5. European conference on accelerators in applied research and technology (ECAART-5) and industrial exhibition
Dates
26-30 Aug 1997
Place
Eindhoven (Netherlands)

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
29052133
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CARBON; FOILS; GOLD IONS; ION BEAMS; LIFETIME; MEV RANGE; TRANSMISSION
Descriptors DEC
BEAMS; CHARGED PARTICLES; ELEMENTS; ENERGY RANGE; IONS; NONMETALS

Optional Information

Notes
2 refs.