Published March 2014 | Version v1
Journal article

An Alternative Empirical Formula for Positive Corona Discharge I-V Characteristics in Point-to-Plate Electrode Geometry

  • 1. Department of Physics, College of Science, Mosul University, Mosul 41002 (Iraq)
  • 2. Department of Physics, College of Education, Dohuk University, Dohuk 42001 (Iraq)

Description

Experimental data are presented for a study on the dependence of the I–V characteristics of the corona discharge on pressure and electrode spacing using point-to-plane electrode configuration. These experimental data are obtained by a fast, automatic computer data-acquisition system. The data are used to suggest an alternative dimensionally self-consistent empirical equation for the parameterization of the I–V curves. The formula eliminates the need for any prior assumptions concerning the inception voltage, as is customary in this type of work

Availability note (English)

Available from http://dx.doi.org/10.1088/1009-0630/16/3/07

Additional details

Identifiers

Publishing Information

Journal Title
Plasma Science and Technology
Journal Volume
16
Journal Issue
3
Journal Page Range
p. 211-218
ISSN
1009-0630

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
46058727
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
CORONA DISCHARGES; DATA ACQUISITION SYSTEMS; DIAGRAMS; ELECTRIC CONDUCTIVITY; ELECTRIC CURRENTS; ELECTRIC POTENTIAL; ELECTRODES; PLASMA PRESSURE; PLATES; PRESSURE DEPENDENCE
Descriptors DEC
CURRENTS; ELECTRIC DISCHARGES; ELECTRICAL PROPERTIES; INFORMATION; PHYSICAL PROPERTIES