Published September 2001 | Version v1
Journal article

Analyses of plant behaviors at the secondary side depressurization during LOCA of PWR

  • 1. Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan)

Description

When high pressure injection systems failed during a small break loss-of-coolant-accident (LOCA) for a PWR, main steam relief valves are opened to operate accumulator systems. However, it is pointed out that the core can be exposed since so-called counter current flow limitation (CCFL) occurs in steam generator (SG) tubes. The possibility of the core exposure by CCFL in a PWR plant was evaluated. First, RELAP5/MOD2 code was modified to be able to calculate CCFL. And then the code was applied to evaluate a 4-loop PWR plant. The LOCA with a rupture 3 inches were analyzed with the following two cases: (1) Only the main steam relief valve of the loop with the rupture is opened. (2) all of the relief valves are opened. It is seen that the CCFL phenomenon occurs in the case (1), however, the core cooling was maintained by the accumulator systems that actuated during the core exposure. On the other hand, the core exposure by CCFL is not observed in the case (2). It is shown that core cooling is promoted by operation of main steam relief valves. (author)

Additional details

Publishing Information

Journal Title
INSS Journal
Journal Volume
8
Journal Page Range
p. 198-205
ISSN
1340-4482

Optional Information

Notes
4 refs., 18 figs.