Analyses of plant behaviors at the secondary side depressurization during LOCA of PWR
- 1. Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan)
Description
When high pressure injection systems failed during a small break loss-of-coolant-accident (LOCA) for a PWR, main steam relief valves are opened to operate accumulator systems. However, it is pointed out that the core can be exposed since so-called counter current flow limitation (CCFL) occurs in steam generator (SG) tubes. The possibility of the core exposure by CCFL in a PWR plant was evaluated. First, RELAP5/MOD2 code was modified to be able to calculate CCFL. And then the code was applied to evaluate a 4-loop PWR plant. The LOCA with a rupture 3 inches were analyzed with the following two cases: (1) Only the main steam relief valve of the loop with the rupture is opened. (2) all of the relief valves are opened. It is seen that the CCFL phenomenon occurs in the case (1), however, the core cooling was maintained by the accumulator systems that actuated during the core exposure. On the other hand, the core exposure by CCFL is not observed in the case (2). It is shown that core cooling is promoted by operation of main steam relief valves. (author)
Additional details
Publishing Information
- Journal Title
- INSS Journal
- Journal Volume
- 8
- Journal Page Range
- p. 198-205
- ISSN
- 1340-4482
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 33000480
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COOLING; COUNTER CURRENT; DEPRESSURIZATION; LIMITING VALUES; LOSS OF COOLANT; MAINTENANCE; NUMERICAL ANALYSIS; OPERATION; PWR TYPE REACTORS; RELIEF VALVES; SECONDARY COOLANT CIRCUITS; STEAM GENERATORS
- Descriptors DEC
- ACCIDENTS; BOILERS; CONTROL EQUIPMENT; COOLING SYSTEMS; ENERGY SYSTEMS; ENRICHED URANIUM REACTORS; EQUIPMENT; FLOW REGULATORS; MATHEMATICS; POWER REACTORS; REACTOR ACCIDENTS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; THERMAL REACTORS; VALVES; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 4 refs., 18 figs.