Variation in radiation doses in paediatric cardiac catheterisation procedures
Creators
- 1. Health Physics Section, Biomedical Physics Dept., King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)
- 2. Biomedical Physics Dept., King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)
- 3. King Faisal Cardiac Centre, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)
Description
Paediatric cardiac catheterisation involves diagnostic and therapeutic procedures that range from simple to complex and can subject paediatric patients to varying radiation doses. The study aims to determine the variation in entrance doses in patients in terms of dose-area product (DAP) values and to investigate the methods for optimising radiation protection. A total of 190 paediatric patients belonging to age groups 0, 1, 5 and 10 y who underwent diagnostic and six selected therapeutic procedures at King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia) were included in the study. Therapeutic procedures include coarctation (COA), patent ductus arteriosus (PDA), radiofrequency ablation, pulmonary, embolisation and septostomy. Fluoroscopy and cine radiography were used in all procedures. Patient demography (weight, age, gender and height), radiographic technique factors, fluoroscopy and cine time, frame rate, and DAP values were taken from patients records. Effective doses for each procedure were estimated from the DAP values. The mean DAP per procedure were analysed for correlation with patient equivalent cylindrical diameter, weight, fluoroscopy time and number of frames. Factors influencing the variation in doses were investigated. Initial results show that PDA occlusion has the highest mean DAP value of 23.21 Gy-cm2, while the diagnostic and septostomy procedures have the lowest value of 7.77 and 6.95 Gy-cm2, respectively. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncn014Additional details
Identifiers
- DOI
- 10.1093/rpd/ncn014;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 129
- Journal Issue
- 1-3
- Journal Page Range
- p. 173-178
- ISSN
- 0144-8420
Conference
- Title
- EC SENTINEL Project workshop. Safety and efficacy for new techniques and imaging using new equipment to support European legislation
- Dates
- 18-20 Apr 2007
- Place
- Delf (Netherlands)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 43120760
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ABLATION; ADOLESCENTS; COMPUTERIZED SIMULATION; FLUOROSCOPY; HUMAN POPULATIONS; INFANTS; MONTE CARLO METHOD; PATIENTS; RADIATION DOSES; RADIATION PROTECTION; RADIOWAVE RADIATION; SAUDI ARABIA
- Descriptors DEC
- AGE GROUPS; ANIMALS; ARAB COUNTRIES; ASIA; BIOMEDICAL RADIOGRAPHY; CALCULATION METHODS; CHILDREN; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; DOSES; ELECTROMAGNETIC RADIATION; MAMMALS; MAN; MEDICINE; MIDDLE EAST; NUCLEAR MEDICINE; POPULATIONS; PRIMATES; RADIATIONS; RADIOLOGY; SIMULATION; VERTEBRATES
Optional Information
- Notes
- 15 refs