Published April 2016 | Version v1
Book

Analysis and policy for the gas intrusion to safety related systems of nuclear power station

  • 1. Taishan Nuclear Power Joint Venture Co., Ltd., Taishan (China)

Description

Non condensed gas intrusion in liquid system could cause serious operation problem and safety related event or accident. Though constructed and managed in high criteria, such events still often reported in nuclear power station. This article analyzes the effect of gas intrusion to the system and equipment of nuclear power station. The standard and practical way of gas content and controlling measures been discussed accordingly. Suggestions are given with analyzing real status of present technical and operation situation. (author)

Part of:
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.2--nuclear energy & power sub-volume

Additional details

Publishing Information

Publisher
Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
978-7-5022-7103-9
Imprint Title
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.2--nuclear energy & power sub-volume
Imprint Pagination
377 p.
Journal Page Range
p. 30-35

Conference

Title
2015 academic annual meeting of China Nuclear Society
Dates
21-24 Sep 2015
Place
Mianyang (China)

Optional Information

Notes
2 tabs., 6 refs.