Published August 2003
| Version v1
Journal article
Design of improved magnetic channel for superconducting cyclotrons by the random search method
Creators
- 1. Variable Energy Cyclotron Centre, Department of Atomic Energy Block-AF, Bidhannagar, Kolkata-700 064 (India)
Description
Magnetic channels are used in cyclotrons and accelerators for extraction of ion beams. Passive magnetic channels use iron bars to lower the magnetic field locally and set up a field gradient. In order that the beam quality does not deteriorate, this field gradient should be highly uniform. We have used the random search method for improving the field quality of a magnetic channel by modifying the geometric parameters of a conventional channel
Additional details
Identifiers
- DOI
- 10.1063/1.1592875;
Publishing Information
- Journal Title
- Review of Scientific Instruments
- Journal Volume
- 74
- Journal Issue
- 8
- Journal Page Range
- p. 3640-3644
- ISSN
- 0034-6748
- CODEN
- RSINAK
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35057566
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- ION BEAMS; IRON; MAGNETIC FIELDS; RANDOMNESS; SUPERCONDUCTING CYCLOTRONS
- Descriptors DEC
- ACCELERATORS; BEAMS; CYCLIC ACCELERATORS; CYCLOTRONS; ELEMENTS; METALS; TRANSITION ELEMENTS
Optional Information
- Notes
- (c) 2003 American Institute of Physics.