Published December 1, 1978 | Version v1
Journal article

Microcomputer controlled energy variation of an isochronous cyclotron and beam handling system

  • 1. Bonn Univ. (Germany, F.R.). Inst. fuer Strahlen- und Kernphysik

Description

An automatic 3 MeV variation of a 30 MeV A-beam was performed in 300 steps at the Bonn Isochronous Cyclotron. A microcomputer in connection with a control unit adjusted the cyclotron and the monochromator system parameters. This combination allowed a direct and precise measurement of broad excitation functions. Using fast magnetic field stabilization an energy-shift was accomplished to an accuracy of better than 1 part in 105 within 20 s. The stability of the beam position on the target was about 0.05 mm. (Auth.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
157
Journal Issue
2
Series
Nucl. Instrum. Methods.
Journal Page Range
311-314
ISSN