Published August 1995 | Version v1
Journal article

Dose monitoring of 125I in the thyroid glands of labelling workers in Beijing and estimation of dose equivalent

  • 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy
  • 2. Beijing Municipal Centre for Hygiene and Epidemic Control, Beijing (China)

Description

The results of 125I monitoring in the thyroid of labelling workers in Beijing are presented. Thyroid of 79 workers engaged in routine 125I-labelling in the several laboratories of Beijing are monitored. Among them seventy-eight workers presents a 125I obvious contamination. The deposition of 125I in the thyroid glands is within the range of 0.01-6.32 kBq. The estimated intake for workers is lower than 1/10 of annual limit of intake. Collective dose equivalent is 27.72 man·mSv. The per capita dose equivalent is 0.35 mSv

Additional details

Publishing Information

Journal Title
Journal of Isotopes
Journal Volume
8
Journal Issue
3
Journal Page Range
p. 156-159.
ISSN
1000-7512