Published July 2014 | Version v1
Journal article

Numerical simulation of primary side for intermediate heat exchanger in CEFR

  • 1. China Institute of Atomic Energy, Beijing (China)

Description

Using commercial CFX code 3D simulation, the 1/6 primary side of intermediate heat exchanger (IHX) in CEFR was investigated. The temperature distribution, velocity distribution and their change trends of IHX primary side were acquired. The results show that the IHX satisfies design requirement. The results will be technical preparation for commissioning and operation of CEFR. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
48
Journal Issue
7
Journal Page Range
p. 1172-1175
ISSN
1000-6931

Optional Information

Notes
7 figs., 2 tabs., 1 ref.; http://dx.doi.org/10.7538/yzk.2014.48.07.1172